Backup equipment comparison

Match equipment to your actual plan.

Compare manufacturer specification snapshots against the same household loads, target and explicit loss assumptions. All tools share the same complete planning workspace.

Home backup planning workspace

Your working draft autosaves on this device. Save named plans to keep alternatives.

Compare verified equipment presets 12 U.S. configurations

Manufacturer specification snapshots reviewed 2026-11-21. Runtime uses your loss assumptions. Unknown specifications remain unresolved; no price or stock claim is made. Original and legacy variants are identified by name.

Enter your actual quote to compare costs. Budget eligibility needs a price; taxes, accessories and installation are separate. Selection and ordering never depend on affiliate links.

Anker SOLIX

F3800 Plus (US)

3.84 kWh · 6,000 W · 120/240 V

needs verification

0 Wh unmet in your 24 h plan.

Surge: not verified; duration not verified.
Limits and source

240 V output cannot be used while charging through 120 V AC. PV input is split across two MPPTs; the total W rating does not verify either array. Single standard 120 V outlet limit is 2400 W.

  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
Manufacturer specification

BLUETTI

Elite 400 (US)

3.84 kWh · 2,600 W · 120 V

needs verification

0 Wh unmet in your 24 h plan.

Surge: not verified; duration not verified.
Limits and source

Use the exact US product revision. Missing surge/port/charging details remain unverified.

  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
Manufacturer specification

EcoFlow

DELTA Pro (original US)

3.6 kWh · 3,600 W · 120 V

needs verification

0 Wh unmet in your 24 h plan.

Surge: not verified; duration not verified.
Limits and source

Original legacy model for existing owners; not DELTA Pro 3. No current stock or price claim. Two-unit accessories are not assumed.

  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
Manufacturer specification

Jackery

Explorer 5000 Plus (US)

5.04 kWh · 7,200 W · 120/240 V

needs verification

0 Wh unmet in your 24 h plan.

Surge: 14,400 W; duration not verified.
Limits and source

7200 W is the total/240 V output; standard 120 V outlets have a lower shared limit. Verify operating mode and installation separately.

  • Assign active loads to documented shared output groups to verify port limits.
Manufacturer specification

Anker SOLIX

C1000X (US, original)

1.06 kWh · 1,800 W · 120 V

fails

1.07 kWh unmet in your 24 h plan.

Surge: not verified; duration not verified.
Limits and source

Original 1056 Wh C1000X, not C1000 Gen 2. SurgePad and bypass ratings are excluded from inverter output.

  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
  • The modeled outage contains unmet appliance energy.
Manufacturer specification

Anker SOLIX

C300 AC (US)

288 Wh · 300 W · 120 V

fails

1.63 kWh unmet in your 24 h plan.

Surge: not verified; duration not verified.
Limits and source

AC model, not C300 DC. SurgePad is not used as a verified motor-start rating. Follow panel compatibility restrictions on the manufacturer page.

  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
  • The modeled outage contains unmet appliance energy.
  • The selected equipment snapshot has no verified startup W rating. Its displayed fallback is the continuous rating.
  • One or more appliance startup durations are unknown.
  • Startup power depends on duration; verify the source can sustain the required starting interval.
Manufacturer specification

BLUETTI

AC180 (US)

1.15 kWh · 1,800 W · 120 V

fails

995 Wh unmet in your 24 h plan.

Surge: not verified; duration not verified.
Limits and source

Power Lifting is excluded from continuous and surge ratings. External power-bank charging is not modeled as integrated battery expansion.

  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
  • The modeled outage contains unmet appliance energy.
Manufacturer specification

BLUETTI

Elite 200 V2 (US)

2.07 kWh · 2,600 W · 120 V

fails

312 Wh unmet in your 24 h plan.

Surge: not verified; duration not verified.
Limits and source

2073.6 Wh is the detailed product title; 2080 Wh is rounded marketing capacity. Power Lifting is not a documented motor-start duration.

  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
  • The modeled outage contains unmet appliance energy.
Manufacturer specification

EcoFlow

DELTA 3 Plus (US)

1.02 kWh · 1,800 W · 120 V

fails

1.09 kWh unmet in your 24 h plan.

Surge: 3,600 W; duration not verified.
Limits and source

X-Boost is excluded. Expansion models and required cables must be checked against the linked specification.

  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
  • The modeled outage contains unmet appliance energy.
Manufacturer specification

EcoFlow

RIVER 3 Plus (US, 286 Wh)

286 Wh · 600 W · 120 V

fails

1.64 kWh unmet in your 24 h plan.

Surge: 1,200 W; duration not verified.
Limits and source

US 286 Wh variant. Do not substitute the 268 Wh variant. Boost modes are not continuous output. Documented extra batteries are listed separately.

  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
  • The modeled outage contains unmet appliance energy.
  • One or more appliance startup durations are unknown.
  • Startup power depends on duration; verify the source can sustain the required starting interval.
Manufacturer specification

Jackery

Explorer 1000 v2 (1070 Wh US)

1.07 kWh · 1,500 W · 120 V

fails

1.06 kWh unmet in your 24 h plan.

Surge: 3,000 W; duration not verified.
Limits and source

Uses the 1070 Wh technical specification, not newer 1024 Wh navigation/promotional variants. Confirm the exact unit label.

  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
  • The modeled outage contains unmet appliance energy.
Manufacturer specification

Jackery

Explorer 2000 Plus (original US)

2.04 kWh · 3,000 W · 120 V

fails

335 Wh unmet in your 24 h plan.

Surge: not verified; duration not verified.
Limits and source

Original 2042 Wh manual revision. Not HomePower 2000 Plus v2. Extra batteries and paired output need separate verification.

  • Per-outlet and shared AC limits are not verified in this snapshot. Confirm the connection before relying on the aggregate W rating.
  • The modeled outage contains unmet appliance energy.
Manufacturer specification

PLAN THE OUTAGE, NOT JUST THE AVERAGE

When does your equipment run?

Scheduled and charging scenarios support up to seven days. A window crossing midnight repeats daily; time is an elapsed local clock, without dates or daylight-saving changes. Duty cycling stays averaged inside each window.

Solar recharge & electrical limits

Flat daylight example, not a local forecast. Default: 400 W, four equivalent sun hours, 75% generation factor and 95% charging efficiency.

Solar generated in outage
0 Wh
Input clipping
0 Wh
Combined-source curtailment
0 Wh
Energy delivered to DC bus
0 Wh
First recharge to full
No full recharge in horizon
Check an entered PV configuration

Evaluate manufacturer-approved configurations; this is not a wiring guide. Blank inputs are unknown. Total array W must match your actual panel count. Check each MPPT separately; a total input W rating does not verify a string.

needs verification · cold array Voc: unknown; array Isc: unknown.

  • PV specifications are incomplete. Solar energy is an assumed projection; voltage, current and MPPT compatibility need verification.
Generator & hybrid charging

Generic entered ratings are assumptions. Fuel is unknown without a documented curve, including at idle or below its lowest point.

Derived from 0.95 gal tank / 8.1 h at quarter load and / 3.2 h at rated load. Interpolation between these points is a planning assumption, not a measured curve. Idle and loads below 25% are unknown. Verify the exact model and operating conditions. Honda specifications

Fuel curve · manufacturer or measured points

Fuel used: 0 gal. Generator AC energy: 0 Wh.

Outdoor operation only.

Never run generators indoors or in garages. Keep at least 20 feet from openings, direct exhaust away and use CO alarms. Never backfeed an outlet. Home circuits and transfer equipment require qualified review.

Scenario buffers & ten-year cost worksheet

Planning buffers vary demand and usable energy, not inverter efficiency. Cost figures are your entries, not published product prices or guaranteed savings.

Upfront: Unknown. Annual modeled fuel: $0. Ten-year estimate: Enter hardware costs and a complete fuel curve when applicable.

Annual fuel scales this outage scenario to your entered annual hours. Ten-year cost includes one entered replacement, maintenance and fuel; no inflation, financing, tax credits, grid savings or automatic lifetime assumptions.

BUILD YOUR LOAD LIST

What needs to stay on?

4 selected

Start with the essentials. Edit estimates to match your equipment.

Browse appliance library 27 starting points
Refrigerator150 W · AC 120 V · estimate
Chest freezer100 W · AC 120 V · estimate
Microwave1,200 W · AC 120 V · estimate
Coffee maker1,000 W · AC 120 V · estimate
Room fan50 W · AC 120 V · estimate
Space heater1,500 W · AC 120 V · estimate
Central air conditioner3,500 W · AC 240 V · estimate
LED light10 W · AC 120 V · estimate
Wi-Fi router15 W · AC 120 V · estimate
Phone charging (USB)10 W · DC 5 V · estimate
CPAP (planning example)60 W · AC 120 V · estimate
Mobility device charger150 W · AC 120 V · estimate
Laptop60 W · AC 120 V · estimate
Computer monitor40 W · AC 120 V · estimate
Large LED television150 W · AC 120 V · estimate
Sump pump (½ HP example)900 W · AC 120 V · estimate
Well pump1,000 W · AC 240 V · estimate
Vacuum cleaner800 W · AC 120 V · estimate
Gas furnace blower400 W · AC 120 V · estimate
Optical network terminal10 W · AC 120 V · estimate
Cable modem12 W · AC 120 V · estimate
Garage-door opener500 W · AC 120 V · estimate
Window air conditioner900 W · AC 120 V · estimate
Mini-split heat pump1,200 W · AC 240 V · estimate
Security camera and recorder20 W · AC 120 V · estimate
CPAP without heated accessories30 W · AC 120 V · estimate
CPAP with heated accessories100 W · AC 120 V · estimate
Planning estimate · 1.19 kWh/day
Startup, connection & source

Reference or measurement source

Planning estimate · 60 Wh/day
Startup, connection & source
Planning estimate · 360 Wh/day
Startup, connection & source

Reference or measurement source

Planning estimate · 240 Wh/day
Startup, connection & source

Hours describe the daily operating window. Duty cycle is the fraction of that window drawing power. See assumptions and source data.

YOUR POWER SOURCE

Battery & inverter

Generic system

Use nominal capacity and output ratings from your system’s manual.

Advanced battery assumptions

Defaults: 90% inverter efficiency, 8 W idle, 10% reserve. Idle runs throughout the outage when AC loads are selected. DC losses and port limits require separate review.

Documented shared output groups

Keep a few options

Save up to 20 plans in this browser. Export a backup before clearing browser data.

Compare saved plans

Up to three plans, each with its own displayed assumptions.

Plan comparison
MeasureWorking plan
Model / sourceaverage / battery
Target24 h
Nominal battery2.05 kWh
Efficiency / reserve90% / 10%
Unmet energy331 Wh
First interruption19.7 h
10-year entered costUnknown
Reference library provenance

All library entries are generic estimates. Source review date: 2026-11-21. No manufacturer-specific specifications are included. Custom values are supplied by you.

RunOnReserve illustrative planning assumptions · estimate. Authored starting points, not measured or manufacturer specifications. Hours, duty and surge values are illustrative; verify on actual equipment.

Ohio Consumers’ Counsel: Watts Driving Up Your Electric Bill? · generic-range. Running watts selected within published generic ranges; hours, duty and surge remain RunOnReserve estimates. Not a verified product specification.

Plan confidently. Connect safely.

Never run a fuel-burning generator indoors, in a garage or near openings. Never backfeed a wall outlet. Home circuits, hardwired loads, transfer equipment, grounding and neutral bonding require qualified review. Medical equipment needs an approved independent backup. Read the safety guide.