Generator and hybrid backup calculator

Plan fuel and battery charging together.

Estimate generator fuel within documented load curves and model generator-to-battery charging during permitted windows. All tools share the same complete planning workspace.

Home backup planning workspace

Your working draft autosaves on this device. Save named plans to keep alternatives.

PLAN THE OUTAGE, NOT JUST THE AVERAGE

When does your equipment run?

Scheduled and charging scenarios support up to seven days. A window crossing midnight repeats daily; time is an elapsed local clock, without dates or daylight-saving changes. Duty cycling stays averaged inside each window.

Solar recharge & electrical limits

Flat daylight example, not a local forecast. Default: 400 W, four equivalent sun hours, 75% generation factor and 95% charging efficiency.

Solar generated in outage
0 Wh
Input clipping
0 Wh
Combined-source curtailment
0 Wh
Energy delivered to DC bus
0 Wh
First recharge to full
No full recharge in horizon
Check an entered PV configuration

Evaluate manufacturer-approved configurations; this is not a wiring guide. Blank inputs are unknown. Total array W must match your actual panel count. Check each MPPT separately; a total input W rating does not verify a string.

needs verification · cold array Voc: unknown; array Isc: unknown.

  • PV specifications are incomplete. Solar energy is an assumed projection; voltage, current and MPPT compatibility need verification.
Generator & hybrid charging

Generic entered ratings are assumptions. Fuel is unknown without a documented curve, including at idle or below its lowest point.

Derived from 0.95 gal tank / 8.1 h at quarter load and / 3.2 h at rated load. Interpolation between these points is a planning assumption, not a measured curve. Idle and loads below 25% are unknown. Verify the exact model and operating conditions. Honda specifications

Fuel curve · manufacturer or measured points

Fuel used: 0 gal. Generator AC energy: 0 Wh.

Outdoor operation only.

Never run generators indoors or in garages. Keep at least 20 feet from openings, direct exhaust away and use CO alarms. Never backfeed an outlet. Home circuits and transfer equipment require qualified review.

Scenario buffers & ten-year cost worksheet

Planning buffers vary demand and usable energy, not inverter efficiency. Cost figures are your entries, not published product prices or guaranteed savings.

Upfront: Unknown. Annual modeled fuel: $0. Ten-year estimate: Enter hardware costs and a complete fuel curve when applicable.

Annual fuel scales this outage scenario to your entered annual hours. Ten-year cost includes one entered replacement, maintenance and fuel; no inflation, financing, tax credits, grid savings or automatic lifetime assumptions.

Compare verified equipment presets 12 U.S. configurations

Manufacturer specification snapshots reviewed 2026-11-21. Runtime uses your loss assumptions. Unknown specifications remain unresolved; no price or stock claim is made. Original and legacy variants are identified by name.

BUILD YOUR LOAD LIST

What needs to stay on?

4 selected

Start with the essentials. Edit estimates to match your equipment.

Browse appliance library 27 starting points
Refrigerator150 W · AC 120 V · estimate
Chest freezer100 W · AC 120 V · estimate
Microwave1,200 W · AC 120 V · estimate
Coffee maker1,000 W · AC 120 V · estimate
Room fan50 W · AC 120 V · estimate
Space heater1,500 W · AC 120 V · estimate
Central air conditioner3,500 W · AC 240 V · estimate
LED light10 W · AC 120 V · estimate
Wi-Fi router15 W · AC 120 V · estimate
Phone charging (USB)10 W · DC 5 V · estimate
CPAP (planning example)60 W · AC 120 V · estimate
Mobility device charger150 W · AC 120 V · estimate
Laptop60 W · AC 120 V · estimate
Computer monitor40 W · AC 120 V · estimate
Large LED television150 W · AC 120 V · estimate
Sump pump (½ HP example)900 W · AC 120 V · estimate
Well pump1,000 W · AC 240 V · estimate
Vacuum cleaner800 W · AC 120 V · estimate
Gas furnace blower400 W · AC 120 V · estimate
Optical network terminal10 W · AC 120 V · estimate
Cable modem12 W · AC 120 V · estimate
Garage-door opener500 W · AC 120 V · estimate
Window air conditioner900 W · AC 120 V · estimate
Mini-split heat pump1,200 W · AC 240 V · estimate
Security camera and recorder20 W · AC 120 V · estimate
CPAP without heated accessories30 W · AC 120 V · estimate
CPAP with heated accessories100 W · AC 120 V · estimate
Planning estimate · 1.19 kWh/day
Startup, connection & source

Reference or measurement source

Planning estimate · 60 Wh/day
Startup, connection & source
Planning estimate · 360 Wh/day
Startup, connection & source

Reference or measurement source

Planning estimate · 240 Wh/day
Startup, connection & source

Hours describe the daily operating window. Duty cycle is the fraction of that window drawing power. See assumptions and source data.

YOUR POWER SOURCE

Battery & inverter

Generic system

Use nominal capacity and output ratings from your system’s manual.

Advanced battery assumptions

Defaults: 90% inverter efficiency, 8 W idle, 10% reserve. Idle runs throughout the outage when AC loads are selected. DC losses and port limits require separate review.

Documented shared output groups

Keep a few options

Save up to 20 plans in this browser. Export a backup before clearing browser data.

Compare saved plans

Up to three plans, each with its own displayed assumptions.

Plan comparison
MeasureWorking plan
Model / sourceaverage / battery
Target24 h
Nominal battery2.05 kWh
Efficiency / reserve90% / 10%
Unmet energy331 Wh
First interruption19.7 h
10-year entered costUnknown
Reference library provenance

All library entries are generic estimates. Source review date: 2026-11-21. No manufacturer-specific specifications are included. Custom values are supplied by you.

RunOnReserve illustrative planning assumptions · estimate. Authored starting points, not measured or manufacturer specifications. Hours, duty and surge values are illustrative; verify on actual equipment.

Ohio Consumers’ Counsel: Watts Driving Up Your Electric Bill? · generic-range. Running watts selected within published generic ranges; hours, duty and surge remain RunOnReserve estimates. Not a verified product specification.

Plan confidently. Connect safely.

Never run a fuel-burning generator indoors, in a garage or near openings. Never backfeed a wall outlet. Home circuits, hardwired loads, transfer equipment, grounding and neutral bonding require qualified review. Medical equipment needs an approved independent backup. Read the safety guide.